Product description
Technical specifications
- Minimum order (MOQ)
- 1 pcs
More from this company
Barış Endüstriyel Enerji Sistemleri A.Ş.
Waste Heat Recovery Boilers
Pressure Vessels ProductCustom designs are made in smoke-tube and water-tube constructions for hot water, steam, superheated steam, thermal oil and hot air production according to waste energy and site conditions. Different outputs such as electricity via ORC conversion, process steam and cooling via absorption chillers can be produced. Main application areas include cogeneration plants, furnace stacks, cement and petrochemical facilities.
Adana · Adana Haci Sabanci Organized Industrial Zone
Barış Endüstriyel Enerji Sistemleri A.Ş.
Economizers
General Heat ExchangersEconomizers are energy recovery equipment designed to increase efficiency in industrial applications such as steam, hot water and thermal oil boilers. Waste heat in flue gases is recovered to reduce fuel consumption. Approximately every 21 °C drop in flue gas temperature means about 1% fuel savings.
Adana · Adana Haci Sabanci Organized Industrial Zone
Related products
Adess Group
Pressure Vessels & Columns
Pressure Vessels ProductCustom-built pressure vessels, columns and towers — from large-scale process towers to reactors, separators and storage vessels, designed to international standards. ADESS GROUP provides solutions for key process equipment, ranging from large-scale towers and columns to various types of pressure vessels. Fabrication follows ASME Section VIII Division 1, API standards (API 650, API 660, etc.), PED 2014/68/EU and CE requirements, in atmospheric, low-pressure and high-pressure designs. Project requirements can include radiographic testing up to 100%, PMI, pickling and passivation, heat treatment and stress relieving, internal pipe coils, pressure-vessel mechanical design software and AutoCAD Mechanical. Materials include carbon steel, stainless steel, nickel alloys, copper alloys and duplex and super duplex.
Teki̇rdağ · Ergene-1 Organized Industrial Zone
Güven Soğutma Üniteleri San. ve Tic. A.Ş.
Vertical Liquid Receivers
Pressure Vessels ProductLiquid receivers are used to accommodate fluctuations in the system and in ambient temperatures. On the high-pressure side they act as a cushion between liquid and hot gas, prevent hot gas from reaching the evaporator and allow liquid in the circuit to settle. They are also used to collect and store refrigerant when service is required. Receivers are manufactured from 0.5 L to 1000 L in accordance with CE 2014/68/EU [PED]. They are installed on the high-pressure side of the refrigeration circuit, at the condenser outlet. In the GVN VLR vertical range, an example rating is 33 bar maximum working pressure, 1 litre volume, Ø89 mm shell, ODS 1/4 in connection, HCFC, HFC, R290 and R717 refrigerants, and -20°C to +130°C operating temperature.
İstanbul
Güven Soğutma Üniteleri San. ve Tic. A.Ş.
Helical Oil Separators
Pressure Vessels ProductHelical oil separators separate oil from discharge gas and return it effectively to the compressor, keeping crankcase oil level and reducing excess oil circulation to raise system efficiency. They are designed for low-pressure oil management and can be used in many systems and with multiple compressors. The internal spiral and stainless filter are more efficient than conventional separators. The gas/oil mix is moved by centrifugal force along the helix so oil particles hit the wall and collect in the bottom chamber. They are designed for scroll and reciprocating compressors; use with screw and rotary compressors is not recommended. A GVN OS.H example is rated 45 bar maximum working pressure, 2.5 L volume, Ø102 mm, ODS 5/8 in, HCFC, HFC, R290, R717 and R-410A, PED CAT.I/CAT.II, -20°C to +130°C.
İstanbul
Güven Soğutma Üniteleri San. ve Tic. A.Ş.
Suction Line Accumulators
Pressure Vessels ProductSuction line accumulators are installed between the evaporator and the compressor. They hold liquid refrigerant so the compressor does not ingest liquid and only vapour is sent on. A U-tube and tube-in-tube design is used for maximum refrigerant flow and minimum oil hold-up: vapour is drawn from the top while oil and liquid collected in the vessel return through a hole in the return tube with the gas. Heat-exchanger accumulators are used when evaporation temperature is very low. They are recommended for parallel compressors, transport refrigeration, two-stage systems, hot-gas defrost, container cooling, long lines, reverse cycle, heat pumps and flooded evaporators. Hold-up capacity should not be below 50% of system charge; 50–70% is advised. A GVN SLA example is 33 bar maximum working pressure, 1.7 L, Ø114 mm, ODS 1/2 in, HCFC, HFC, R290 and R717, PED CAT.I/CAT.II, -20°C to +130°C.